Technical Drawing
Technical Drawing
Model no. and Dimensions
Application
All seagoing vessels transiting suez canal
Features
Protection degree : IP56
Have a controllable split glass reflector
Giving either a single light beam or two separate light
beams each of 5degrees in the horizontal level with
a dark middle sector between 0 and 10 degrees
Fitted with a pressure relief valve and exhaust cock,
for connection to a 5 metre length of flexible hose
Have two lamps installed, one as a spare with external
switchover arrangement in case of a burn-out
ex-proof plug and receptacle with are available for
instsllation in hazardous areas.
Materials
Body : Stainless steel sheet
Arm : Aluminium
Reflector : Split silver- plated parabolic mirror
Front glass : Tempered glass
Finish
Powder coated white N-9.3
and enamelled up to 70~80? thickness
Specification
Light sources : Halogen lamp / 2,000W, 3,000W
Lamp base : G38 / Horizontal rotation 350?
Vertical movement upward 40?/ downward 35?
Cable entry : One(1) cable glands M24x1.5
(Max.diameter 17mm cable)
Mounting : 6 mounting holes, dia. 19mm
Voltage and frequency : AC220V 60Hz are standard
Others on request
Optional
With 3M cable(TPNP 1.5)