Construction Design

marine-fire-resistant-power-and-control-cable-spec
  1. Circular standard plain annealed high conductivity copper wire.
  2. Mica glass tape
  3. Cross-linked polyethylene, XLPE.
  4. Polyester tape wrapping.
  5. Plain copper wire braid.
  6. Flame retardant, Low smoke halogen-free compound, SHF1, black.

Specifications

Application Amoured cable for fixed installations of marine and offshore purposes. For power and control systems.
Rated Voltage 0.6/1KV
Maximum conductor operating temperature 90oC
Insulation resistance : ≥1000Mohm*km
Test Voltage 3.5KV/5min
One core: Natural
Two cores: Blue, Brown
Three cores: Brown, Black, Grey
Three cores: Brown, Black, Gray
Four cores: Blue, Brown, Black, Gray
Five cores or more: Black cores with white numbering
Standard reference IEC 60228, IEC 60092-350,
IEC 60092-351, IEC 60092-353,
IEC 60092-359, IEC 60332-3A,
IEC 60754, IEC 61034,IEC 60331
marine-fire-resistant-power-and-control-cable-table-1
marine-fire-resistant-power-and-control-cable-table-2
Those indicated with(*) represent round conductor
*We reserve the right to alter this specification without prior notice.